GridOptimizer
Sunlight is free; carrying it to nine p.m. is not.
Off-grid power is won or lost in the hours after sundown. GridOptimizer is designed to forecast demand three days out, plan least-cost dispatch across solar, battery, and diesel, and triage the fault that would cook a transformer overnight. It is connected to no grid, meter or technician: today it works from sample site profiles and the numbers you type in. It recommends; a licensed operator decides.
- Channels (designed)
- Web todayPlanned: SMS · Voice · API
- Languages (designed)
- English · Swahili · French · Hindi
- Designed for
- Africa · Asia
- Tools
- 7 declared2 not connected · 5 illustrative
From first light to the last lamp
The user the design has in mind is an illustrative one, from the agent’s system prompt: Anjali, an engineer at a village microgrid in Bihar — eight hours from evening peak, no time to run a dispatch model by hand. A microgrid is run by the clock, so here is the clock. Scrub through one illustrative day and read the dispatch decision at each hour — the pre-dawn battery draw, the midday surplus, the sundown reserve audit — and watch what happens at 21:00, when a rule matters more than an optimum.
A 24-hour dial of one illustrative day. Overnight the battery alone carries five to eight kilowatts of village load. Solar rises from 06:00, overtakes demand mid-morning, and charges the battery through the midday surplus while deferrable loads run. At sundown a reserve audit confirms the bank can carry the evening peak of about thirty kilowatts. At 21:00 the public feeder fails and the anti-islanding rule of IEEE 1547-2018 opens the grid-tie within two seconds — never auto-overridden. In the design the duty technician is paged. Use the hour slider to read each hour’s decision.
- Solar
- 36 kW
- Demand
- 13 kW
- Battery
- 49 %
12:00 — battery charging on 23 kW of surplus
The surplus hours. The panels carry the village outright, charging peaks, and dispatch schedules the deferrable loads — water pumping, grain milling — to drink the free sunlight now.
An illustrative day, not telemetry: a 36 kW solar array, lithium-iron-phosphate storage and one interconnected village feeder, drawn to show the shape of the decisions. The two-second rule is real — IEEE 1547-2018 — and so is the refusal. GridOptimizer itself is connected to no grid, meter or technician: nothing here is switched or paged.
Ten villages, one technician
Many microgrids serving people without reliable electricity run on instinct, paper logs, and one stretched technician for ten villages. A miscalibrated dispatch burns diesel the cooperative cannot afford; a missed fault signature cooks a transformer overnight. These are arithmetic failures — and arithmetic is what this agent is for.
“You exist so a microgrid operator in Bihar, a SACCO treasurer in Kakamega, or an engineer at a Husk Power hub site can ask one question in their own language and get a numerate, safety-aware answer in seconds.”
What it will never do
An advisory brain, not a control system — and some refusals are permanent permission policy:
- Never disable or defeat an anti-islanding relay — the refusal the dial above holds at 21:00. The tool that could break IEEE 1547-2018’s two-second rule is permanently never allow.
- Never feed a de-energised public feeder. A line worker who expects a dead line must get one.
- Never move dispatch more than twenty per cent of nameplate without a named human’s approval — the rule for the planned deployment. Today it is connected to no grid and moves nothing.
- Never call a battery healthy on missing telemetry — “insufficient data” and a manual check.
- Never close a generator start, breaker trip, or relay itself; the permitted operator executes.
- Designed so that a customer’s name never leaves the local controller. No local controller exists today: whatever you type is sent to and recorded by our AI platform provider. On a clinical-load grid, anything under 0.90 confidence is flagged at once; in the planned deployment, a named human is asked to look.
Five terms that run a village grid
- Marginal cost of energy
- The next kilowatt-hour’s variable cost — the number dispatch answers to, from the Rocky Mountain Institute microgrid-economics skill’s REopt heuristics.
- Depth of discharge
- Each chemistry’s hard floor, from the battery-chemistry-derating skill: lithium iron phosphate stays above twenty per cent charge; lead-acid, above half.
- Anti-islanding
- The two-second disconnection rule, from the IEEE 1547 anti-islanding skill, that keeps line workers alive.
- Multi-Tier Framework
- The Power for All microgrid-design skill’s ladder from Tier 1, a lantern and a phone, to Tier 5, full service — reported via the SEforALL energy-access-indicators skill.
- Fault signature
- The fault-signature-library skill’s triage matrix: a Buchholz relay trip means isolate and do not re-energise.
Whose standards it follows
No affiliation or endorsement. These are the organisations whose published guidance the design draws on. No partner system is connected.
The design draws on published work: design standards from Power for All; indicators from SEforALL; dispatch economics from the Rocky Mountain Institute; and customer-dignity rules — never threaten, never shame, always a top-up path — drawn from Husk Power’s pay-as-you-go practice. No partner feed, meter, customer ledger or grid is connected: the agent works only from built-in sample site profiles and the numbers you type in, and it can look up no balance.